  Datasheet File OCR Text:
 MITSUMI
System Reset PST574
System Reset
Monolithic IC PST574
Outline
This IC functions in a variety of CPU systems and other logic systems, to detect power supply voltage and reset the system accurately when power is turned on or interrupted. This ultra-low current consumption low reset type system reset IC has a built-in fixed delay time generating circuit. It is ideal for use in multi-CPU systems because a fast-rising output waveform can be obtained.
Features
1. 2. 3. 4. 5. Ultra-low current consumption Low operating limit voltage Output current high for ON Hysteresis voltage provided in detection voltage Built-in delay circuit with excellent delay time temperature characteristics 6. 10 ranks of detection voltage ICCH=7.5A typ. ICCL=400A typ. 0.65V typ. 30mA typ. 50mV typ. 50mV typ. PST574 C : 4.5V typ. D : 4.2V typ. E : 3.9V typ. F : 3.6V typ. G : 3.3V typ. H : 3.1V typ. I : 2.9V typ. J : 2.7V typ. K : 2.5V typ. L : 2.3V typ.
Package
MMP-3A (PST574 M) TO-92A (PST574 ) contains detection voltage rank .
*
Applications
1. 2. 3. 4. 5. Reset circuits in microcomputers, CPUs and MPUs (especially multi-CPU sets) Logic circuit reset circuits. Battery voltage check circuits. Back-up power supply switching circuits. Level detection circuits.
Pin Assignment
1 2 3
VCC GND VOUT
1
3
1 2
VCC GND VOUT
2
3
1
2
3
MMP-3A
TO-92A
MITSUMI
System Reset PST574
Equivalent Circuit Diagram
Absolute Maximum Ratings
Item Storage temperature Operating temperature Power supply voltage Allowable loss
(Ta=25C) Symbol TSTG TOPR VCC max. Pd Rating -40~+125 -20~+75 -0.3~10 200 (MMP-3A) 300 (TO-92A) Units C C V mW
Electrical Characteristics
Item
(Ta=25C) (Except where noted otherwise, resistance unit is ) Measurement Measurement conditions circuit PST574C PST574D PST574E PST574F RL=470 PST574G 1 VOL < 0.4V = PST574H VCC=H L PST574I PST574J PST574K PST574L 1 RL=470, VCC=L H L 1 1 1 1 1 2 2 1 1 1 RL=470, Ta=-20C~+75C VCC=VS min.-0.05V, RL=470 VCC=7.5V VCC=VS min.-0.05V, RL= VCC=VS typ./0.85V, RL= 1 RL=4.7k, CL=100pF 1 RL=4.7k, CL=100pF < RL=4.7k, VOL = 0.4V VCC=Vs min.-0.05V, RL=0 2 Ta=-20C~+75C, RL=0 Min. Typ. Max. Units 4.3 4.0 3.7 3.4 3.1 2.9 2.75 2.55 2.35 2.15 25 4.5 4.2 3.9 3.6 3.3 3.1 2.90 2.70 2.50 2.30 50 0.01 0.1 400 7.5 400 6 0.65 30 0.4 0.1 650 12.0 600 20 0.85 4.7 4.4 4.1 3.8 3.5 3.3 3.05 2.85 2.65 2.45 100
Symbol
Detection voltage
VS
V
Hysteresis voltage Detection voltage temperature coefficient Low-level output voltage Output leakage current Circuit current while on Circuit current while off "H"transport delay time "L"transport delay time Operation limit voltage Output current while on I Output current while on II
VS VS/ T VOL IOH ICCL ICCH tpLH tpHL VopL IOL I IOL II
mV %/C V A A A S S V mA mA
* * *
250
8 5
* *
1 : tpLH : VCC=(VS typ.-0.4V) 2 : VCC=VS min.-0.15V
(VS typ.+0.4V), tpHL : VCC=(VS typ.+0.4V)
(VS typ.-0.4V)
MITSUMI
System Reset PST574
Measuring Circuit
[1] [2]
0.8V 4.9 VS 4.1
0V
Note: Input model is an example for PST574C.
Characteristics
Vcc vs. VOUT
8 7 6
(Example: PST574C)
Vcc vs. Icc
500 400 300
Ta=75C Ta=-20C Ta=25C
VOUT (V) 4
3 2 1 0 1
Ta=-25C Ta=25C Ta=75C
5
ICC (A)
200 100 0 0 1 2 3 4 5 6 7 8
2
3
4
5
6
7
8
VCC (V) VCC (V)
Vs vs. Ta
4.53 4.52 4.51
Vs vs. Ta
80 70 60
VS 4.50 (V)
4.49 4.48 4.47 -40 -20 0 20 40 60 80
VS 50 (mV)
40 30 20 -40 -20 0 20 40 60 80
Ta (C)
Ta (C)
MITSUMI
System Reset PST574
IoL vs. Ta
60 50
VoL vs. Ta
300 250
IOL 40 (mA)
30 20 10 -40 -20 0 20 40 60 80
VOL 200 (mV)
150 100 50 -40 -20 0 20 40 60 80
Ta (C)
Ta (C)
ICCH vs. Ta
10 9 8
ICCL vs. Ta
500
lCCH (A)
7 6 5 4 -40 -20 0 20 40 60 80
ICCL 400 (A)
300
-40
-20
0
20
40
60
80
Ta (C)
Ta (C)
tPLH vs. Ta
600 500 450
Pd vs. Ta
300
tPLH (S)
200
400 350 300 250 -40 -20 0 20 40 60 80
Pd (mW)
100
0 0 25 50 75 100 125
Ta (C)
Ta (C)
Timing Chart
7 6 5 4 VCC /VOUT 3 (V) 2 1 0 VCC VS VOUT
Time RESET ON OFF
Undefined
MITSUMI
System Reset PST574
Application circuits
1. Normal hard reset
Note: Connect a capacitor between IC pins 1 and 2 if VCC line impedance is high.
2. Battery checker (LED ON for high voltage)
Note: Connect a capacitor between IC pins 1 and 2 if VCC line impedance is high.
3. Battery checker (LED ON for low voltage)
Note: Connect a capacitor between IC pins 1 and 2 if VCC line impedance is high.
4. Hysteresis voltage UP method
When increasing hysteresis voltage for stable system operation, determine RH as follows and connect externally. However, ICCH is -5000PPM/C, so perform temperature compensation at RH when using over a wide temperature range. Hysteresis voltage UP amount ( Vsup) is Vsup . . RH ICCL = Total hysteresis voltage ( Vstotal) is Vstotal . . Vs + Vsup = (Operation will be destabilized if RH is raised too much.) Note: Connect a capacitor between IC pins 1 and 2 if VCC line impedance is high.